Projects

Inside the old fireplace, a masonry heater

Saône-et-Loire · Joncy (71460) · 2026

Masonry heater in an old fireplace in Saône-et-Loire: image of the finished work, corner bench, log niche and glazed firebox
Data sheet
Year2026
CommuneJoncy (71460)
ConduitTubage inox double peau Ø 180 mm, isolé en vrac
Type

Assembly, step by step

  1. Foundation and footing — Inside the old fireplace, a masonry heater
    01Foundation and footingBase prepared in the hearth: air supply and insulated ducts
  2. Installing the heater core — Inside the old fireplace, a masonry heater
    02Installing the heater coreCast-iron firebox set on its support, stainless-steel exchanger around it
  3. Smoke channels — Inside the old fireplace, a masonry heater
    03Smoke channelsCeramic-module flue path within the footprint of the bench
  4. Cladding — Inside the old fireplace, a masonry heater
    04CladdingRefractory slabs around the bench and firebox, before rendering

An old stone fireplace, at Joncy (Saône-et-Loire), turned into a bespoke masonry heater. The original lintel and corbels stay in place: the heater sits in the hearth, and its heated bench runs along both walls. Here is how we designed and built it.

Old fireplace with stone corbels and cast-iron fireback before the work, 3D views of the future masonry heater resting on the lintel
The starting point: the original fireplace, and the 3D views of the future heater resting on the lintel.

Keeping the old fireplace, giving it a new role

An open fireplace heats poorly. The fire burns fast, and much of the heat goes back up the flue along with the room air. Yet this old, renovated house had what is needed for proper wood heating: a wide hearth and an existing flue.

Rather than demolish, we kept what gives the room its character — the stone lintel and its corbels — and built the heater within the footprint of the hearth. The old fireplace becomes the envelope of the masonry heater. The fire now burns in a closed firebox, and its heat is stored instead of escaping.

Sizing before drawing

A masonry heater is sized on the needs of the house, not on the size of the old fireplace. The design calculation, based on the data supplied for this pre-1975 house at 240 m above sea level, puts the heat losses at around 8 kW. The heater is designed to standards EN 15544, which governs the sizing of site-built heat-storage heaters, and EN 13384, which covers flue calculation.

Then come the drawings: wall insulation, bench footprint, niches, air supply. Every cladding element is dimensioned before assembly begins. To understand why the mass matters more than the flame, see how a masonry heater works.

Preparing the masonry heater in the old fireplace: insulation boards on the walls and the bench outline marked on the floor
Before the mass, the insulation: the hearth walls are lined with insulation boards and the heater's footprint is marked out on the floor.

The heater is airtight. Combustion air comes from outside through a duct that passes through the old masonry and opens beneath the firebox: the fire does not consume room air, which matters in a house fitted with mechanical ventilation (VMC).

Combustion air supply of the masonry heater opening at floor level in the old fireplace, between the original flagstones
The combustion air supply opens at the heart of the hearth, between the original flagstones.

The core: a cast-iron firebox with controlled combustion

The firebox is a cast-iron Eurotherm 12 Automatique, designed for heat-storage stoves: air injection at several points, electronic combustion control, Wi-Fi operation. It takes 7.5 to 20 kg of wood per burn. The electronics meter the air over the course of the burn; the option of an end-of-circuit damper was not taken up. The two approaches are compared on our page about regulating a masonry heater.

Around the firebox, a passive stainless-steel tube exchanger is provided to preheat domestic hot water, by indirect recovery and with no contact with the flames. The principle is explained on the hydraulic heat exchangers page of our Cœur de Foyer shop.

The heated bench, module by module

Leaving the firebox, the flue gases enter a heat store made of interlocking ceramic modules. The path rises, turns horizontal, then runs the full length of the corner bench before reaching the flue. This journey turns the heat of the flue gases into stored heat: the ceramic absorbs it during the burn, then releases it slowly as radiant heat.

Ceramic modules of the heat store at the firebox outlet, start of the flue path towards the bench
Start of the path: the ceramic modules rise from the firebox, then turn horizontal towards the bench.

The whole is then clad with refractory slabs, then rendered. Two niches are built into the cladding: a plate-warmer above the firebox, closed by a double-leaf grille, and a tall log niche beside it.

Inside the old fireplace flue: liner and insulation

The original flue is not used as it is. It receives a Ø 180 mm twin-wall stainless-steel flue liner, and the space between the liner and the masonry is filled with loose-fill insulation. The open fireplace is sealed airtight at the bottom to hold this insulation in.

Stainless-steel flue liner in the old fireplace flue, embedded in bead insulation
The stainless-steel liner, embedded in its bead insulation.
Stainless-steel liner emerging at the top of the chimney stack, beneath the chimney cap
At the top of the stack, the liner emerges beneath the chimney cap.

The result, and what remains to be fitted

Pale render, straight lines, glazed firebox beneath the stone lintel: the masonry heater fits into the old fireplace without erasing it. The bench follows the two stone walls up to the heater, and the log niche keeps the wood within reach.

Masonry heater in the old fireplace: pale render, glazed firebox, log niche and corner bench, before the stone seats are fitted
The masonry heater in the old fireplace, with its corner bench, before the stone seats are fitted.
Front of the masonry heater: double-leaf grille of the plate-warmer, glazed firebox door and log niche beneath the stone lintel
The front, beneath the lintel of the old fireplace: plate-warmer behind its double-leaf grille, glazed firebox, log niche.
Corner heated bench along the stone walls of the old fireplace
The heated bench runs along the two stone walls up to the heater.

One last stage is still to come: the dressed-stone bench seats, entrusted to a stonemason, and with them the LED strip built into the bench. The opening image of this page shows the work once these seats are in place.

Key points — An old fireplace can house a masonry heater without losing its character: keep the stone, line and insulate the flue, bring in air from outside, and size the heater on the needs of the house, not on the size of the hearth.

Other projects follow the same logic. Also in Saône-et-Loire, at Viré, an insert becomes a masonry heater. In the Cher, the heater takes its place in the fireplace opening. Do you have an open fireplace and a house to heat? Request a study of your project.


Other projects